Real-time biomolecule detection using GMR chip-based sensor with green-synthesized Fe3O4/rGO nanocomposites as magnetic labels

Closed

Zurnansyah, Putri Dwi Jayanti, Larrisa Jestha Mahardhika, Hafil Perdana Kusumah, Harlina Ardiyanti, Nur Aji Wibowo, Nurul Imani Istiqomah, Nining Sumawati Asri, Julia Angel, Edi Suharyadi

2024 Sensors and Actuators A: Physical Vol. 375 Article Cited by 21 SDG 3SDG 17 Quartile

Abstract

The availability of a rapid, low-cost, and easy-to-use device to monitor the bovine serum albumin (BSA) level in human blood and urine is vital in early disease detection. This work reports a biosensor system based on a giant magnetoresistance (GMR) chip as a transducer integrated with Fe3O4/rGO magnetic labels for BSA protein detection. The commercial chip AAL024 is utilized as the GMR sensor, combined with an Arduino microcontroller (AM) and a basic differential amplifier to acquire the digital output voltage. The Fe3O4/rGO nanocomposites were synthesized by a hybrid process based on the green synthesis route utilizing plant extracts. The nanocomposites exhibit superparamagnetic behavior, affecting the magnetic label detection quality. In investigating sensor performance, Fe3O4/rGO nanocomposites can generate sufficient stray fields under a 4 Oe of bias magnetic field (HB). A larger net stray field is produced by a higher concentration of magnetic labels, which suggests that there are more Fe3O4 nanoparticles attached to the sensor surface. Further, the effectiveness of the biosensor was evaluated by detecting the BSA protein. As a result, a high sensitivity of 22.98 mV/(mg/mL) and a low limit of detection (LOD) of 0.3 mg/mL were obtained in detecting Fe3O4/rGO(5:1)/BSA with a voltage signal that can be collected in 30 s. Besides its high sensitivity, low LOD, and fast detection, the sensor exhibits remarkable reproducibility and stability, as evidenced by the relative signal deviation (RSD) range of 1.1 – 5.6%. These findings demonstrate that the GMR chip-based sensor integrated with Fe3O4/rGO magnetic labels provides a simple biosensor system with real-time electronic readout. © 2024 Elsevier B.V.

Affiliations

Department of Physics, Universitas Gadjah Mada, Yogyakarta, Indonesia; Department of Physics, Institut Teknologi Sumatera, Lampung, Indonesia; Department of Physics, Universitas Kristen Satya Wacana, Salatiga, Indonesia; Research Center for Advanced Materials, National Research and Innovation Agency, Tangerang Selatan, Indonesia; Research Center for Nanotechnology Systems, National Research and Innovation Agency, Tangerang Selatan, Indonesia

Research at a Glance

Premium content — register to unlock

Research at a Glance

Register to unlock

Topics & SDG Alignment

Premium content — register to unlock

Topics & SDG Alignment

Register to unlock

Collaboration

Premium content — register to unlock

Collaboration

Register to unlock

Author Profile (Selected)

Premium content — register to unlock

Author Profile (Selected)

Register to unlock

References Overview

Premium content — register to unlock

References Overview

Register to unlock

Journal & Source

Premium content — register to unlock

Journal & Source

Register to unlock

Metadata & Integrity

Premium content — register to unlock

Metadata & Integrity

Register to unlock