Two spin-valve GMR thin films on half wheatstone bridge circuit for detecting green-synthesized Fe3O4@Ag nanoparticles-labeled biomolecule

Closed

Shania Garcia, Ni'matil Mabarroh, Mahardika Yoga Darmawan, Nur Aji Wibowo, Harlina Ardiyanti, Rivaldo Marsel Tumbelaka, Nurul Imani Istiqomah, Edi Suharyadi

2023 Materialia Vol. 32 Article Cited by 11 SDG 9SDG 14 Quartile

Abstract

The availability of low-cost, rapid, and easy-to-use instruments for detecting biomolecules is critical in giant magnetoresistance (GMR) based biosensors. This research reports the performance of two spin-valve (SV) GMR thin films on half Wheatstone bridge circuits for detecting biomolecules. The SV thin films with the structure of Ta(2 nm)/Ir20Mn80(10 nm)/Co90Fe10(3 nm)/Cu(2.2 nm)/Co84Fe10B4(10 nm)/Ta(5 nm) used as sensing element was fabricated using RF magnetron sputtering on Si/SiO2 substrate. The Fe3O4 magnetic nanoparticles as a label were synthesized by coprecipitation method based on the green synthesis route using Moringa oleifera (MO) extract. Furthermore, the utilization of Ag nanoparticles to form Fe3O4@Ag was also green-synthesized by the aqua-solution method using MO extract. The nanoparticles exhibited soft ferromagnetic behavior with the saturation magnetization of 55.0 emu/g for Fe3O4 and 43.4 emu/g for Fe3O4@Ag. A small amount of magnetic nanoparticles-ethanol solution was dropped onto each sensing element surface on half Wheatstone bridge. For comparison, one thin film was also investigated as a quarter Wheatstone bridge circuit. Based on this research, two sensors have faster magnetic switching and saturation than one sensor, confirmed by the left-shifting of Hs(sv) from 12.4 Oe down to 10.5 Oe for two sensors of the Fe3O4 sample. BSA is used as a biomarker to observe the performance of biosensors. The sensor on the half-bridge circuit in detecting Fe3O4@Ag/BSA achieved a better sensitivity of 0.51 mV/mg/mL than that of the quarter bridge of 0.46 mV/mg/mL. A small limit-of-detection of 0.5 mg/mL was achieved for Fe3O4@Ag/BSA. Moreover, the excellent reproducibility and stability of the sensor were confirmed by relative signal deviation ranges of 2–13 % for 60 s. Therefore, the half-bridge configuration is reliable for achieving competitive performance with green-synthesized magnetic labels in GMR as biosensors in encouraging more responsive detection. © 2023 Acta Materialia Inc.

Affiliations

Department of Physics, Universitas Gadjah Mada, Yogyakarta, Indonesia; Department of Physics, Institut Teknologi Sumatera, Lampung, Indonesia; Department of Physics, Universitas Kristen Satya Wacana, Salatiga, Indonesia

Research at a Glance

Premium content — register to unlock

Research at a Glance

Register to unlock

Topics & SDG Alignment

Premium content — register to unlock

Topics & SDG Alignment

Register to unlock

Collaboration

Premium content — register to unlock

Collaboration

Register to unlock

Author Profile (Selected)

Premium content — register to unlock

Author Profile (Selected)

Register to unlock

References Overview

Premium content — register to unlock

References Overview

Register to unlock

Journal & Source

Premium content — register to unlock

Journal & Source

Register to unlock

Metadata & Integrity

Premium content — register to unlock

Metadata & Integrity

Register to unlock